Barnsley Standards
You can apply to join the Rentsmart Landlord Accreditation Scheme by completing the application form.  In order to be accepted, you must agree to work to a code of management and meet certain housing standards. These standards are related to single-let properties. If you have a house in multiple occupation (HMO), you will need to refer to the Council’s amenity standards for HMOs. This gives reassurance to your current and prospective tenants that you are a responsible landlord. Barnsley Standards include:
 
Property
The property must be structurally stable and free from disrepair.
There must be no hazards identified from a HHSRS inspection.
If the property is furnished, all furnishings must be clean and comply with Furniture and Furnishings Fire Safety Regulations.
The property must be clean and decorated to a good standard, and the garden areas must be maintained.
There must be adequate waste disposal facilities.
All the appliances must be in working order with instructions provided.
A legionella risk assessment must be completed.

The external areas (gardens, yards, driveways) of the property must be maintained and in a good condition.

 
Gas Safety
All gas installations must comply with current regulations and be checked annually.
A copy of the Gas Safety Certificate must be provided to the tenant.
 
Electrical Safety
All electrical installations must comply with current regulations and be checked in accordance with the certificate.
A copy of the Electrical Safety Certificate must be provided to the tenant.
The property must have a minimum number of electrical socket outlets as described below.
Hall, stairs & landing: 1 single (subject to size and practicability)
Living room: 3 double
Kitchen: 3 double above worktop, plus 1 dedicated for fridge/fridge/freezer, 1 dedicated for washing machine (where applicable) & 1 dedicated for cooker (where applicable)
Bedrooms: 2 double (single) & 3 double (double)
 
Heating
The whole house must be capable of being heated to between 18oC & 22oC.
The tenants must be able to control the heating.
 
Energy Efficiency
The property must have a valid Energy Performance Certificate (EPC) with a rating of A-E.
 
Kitchen Facilities
The property must have:
A sink, drainer and cleanable splash back
A cooker isolation point
Worktops of at least 100cm x 50cm
Dry food storage cupboards
Space for a fridge freezer and washing machine
Working mechanical ventilation
 
Bathroom Facilities
The property must have:
• An internal WC for the exclusive use of tenants
A fixed bath or shower and wash basin with hot and cold water and splash back
An effective drainage system for foul, waste and surface water
Dry food storage cupboards
Space for a fridge freezer and washing machine
Working mechanical ventilation
 
 
Doors & Windows
The external doors must be watertight and fitted with a 5-lever lock or equivalent.
Windows lower than 80cm from floor level must be fitted with safety glass.
 
Lighting
Each room must have at least 1 permanent light fitting.
The property must have a working external security light.
 
Ventilation
The property must have adequate ventilation to all rooms, either through openable windows, trickle vents, permanent wall vents,s or mechanical ventilation.
The property must have working mechanical ventilation in kitchens and bathrooms.
 
Fire Protection
The property must have mains-wired interlinked smoke detectors with at least 1 smoke detector per storey.
 
Carbon Monoxide Protection
If the property has a solid fuel appliance, a carbon monoxide alarm must be fitted in each room where a solid fuel appliance is located.
The property must have a carbon monoxide alarm fitted where the gas boiler is located.
 
Stairs & Handrails
The property must have handrails fitted to all internal & external staircases, including the cellar.