You can apply to join Barnsley Landlord Accreditation Scheme by completing the application form however you must agree to work to a code of management and meet certain housing standards. These standards are related to single let properties however if you have a house in multiple occupation (HMO), landlords will need to refer to the Council’s amenity standards for HMOs. This gives reassurance to your current and prospective tenants that you are a responsible landlord. Barnsley Standards include:
Property
- The property must be structurally stable and free from disrepair
- There must be no hazards identified from a HHSRS inspection
- If the property is furnished, all furnishings must be clean and comply with Furniture and Furnishings (Fire) (Safety) Regulations?
- The property must be clean and decorated to a good standard along with the garden areas being maintained
- There must be adequate waste disposal facilities
- All the appliances must be in working order with instructions provided
- A legionella risk assessment must be completed
- The external areas (gardens, yards, driveways) of the property must be maintained and in a good condition
Gas Safety
- All gas installations must comply with current regulations and checked annually
- A copy of the Gas Safety Certificate must be provided to the tenant
Electrical Safety
- All electrics installations must comply with current regulations and checked in accordance with the certificate
- A copy of the Electrical Safety Certificate must be provided to the tenant
- The property must have minimum electrical socket outlets
-
- Hall, stairs & landing: 1 single (subject to size and practicability)
- Living room: 3 double
- Kitchen: 3 double above worktop plus 1 dedicated for fridge/fridge/freezer, 1 dedicated for washing machine (where applicable) & 1 dedicated for cooker (where applicable)
- Bedrooms: 2 double (single) & 3 double (double)
Heating
- The whole house must be able to be heated to between 18oC & 22oC
- The tenants must be able to control the heating
Energy Efficiency
- The property must have a valid Energy Performance Certificate (EPC) with a rating of A-E
Kitchen Facilities
- The property must have:
-
- A sink, drainer and cleanable splash back
- A cooker isolation point
- Worktops at least 100cm x 50cm
- Dry food storage cupboards
- Space for a fridge freezer and washing machine
- There must be working mechanical ventilation
Bathroom Facilities
- The property must have:
-
- An internal WC for the exclusive use of tenants
- A fixed bath or shower and wash basin with hot and cold water and splash back
- An effective drainage system for foul, waste and surface water
- There must be working mechanical ventilation
Doors & Windows
- The external doors must be watertight and fitted with a 5-lever lock or equivalent
- Windows lower than 80cm from floor level must be fitted with safety glass
Lighting
- Each room must have at least 1 permanent light fitting
- The property must have a working external security light
Ventilation
- The property must have adequate ventilation to all rooms either through openable windows, trickle vents, permanent wall vents or mechanical ventilation
- The property must have working mechanical ventilation in kitchens and bathrooms
Fire Protection
- The property must have mains wired interlinked smoke detectors with at least 1 smoke detector per storey
Carbon Monoxide Protection
- If the property has a solid fuel appliance the property must have a carbon monoxide alarm fitted in each room where a solid fuel appliance is located
- The property must have a carbon monoxide alarm fitted where the gas boiler is located
Stairs & Handrails
- The property must have handrails fitted to all internal & external staircases, including the cellar